+39 030 320 301 [email protected]

LOW VOLTAGE CAPACITOR BANKS

LOW-VOLTAGE CAPACITOR BANKS

Gruppo Energia power factor correction systems help you save 25% or even more on your monthly power bills, thanks to an effective and correct compensation of the reactive power.

Reactive power is usually caused by various types of loads. If your cosϕ value is lower than 0.95, you need to pay a penalty that is added to your utility bills.

 Thanks to our industrial capacitor banks, your cosϕ is automatically modified, and this allows you to save money.

In our wide range of products, you can find the most suitable solution for your needs and your network, such as PFC capacitor banks with duty contactors or thyristor switching.

 For systems with high level of harmonic distortion, all types of capacitors panels can be equipped with harmonic filters of different detuned frequencies such as 189 Hz, 134 Hz, 210 Hz, 230 Hz, 160 Hz or 250 Hz, which correspond to P =5,67%, P=7% and P=14%.

 Thanks to the efficiency of our components, which have been designed, produced and tested in our company in Italy, you will be able to recoup the initial investment in a short time.

Moreover, our capacitor banks increase the performance of your production line, by:

  • reducing the frequency of voltage sags (which are unfavourable for the production process);
  • avoiding nuisance tripping and supply interruptions.

 

Further benefits of Gruppo Energia power factor correction systems: 

  • Saving money by paying lower utility bills;
  • Reduced demand charges thanks to the improvement of power factor;
  • Increased load carrying capabilities in existing circuits, as a consequence of the reduction of the current carried by each circuit;
  • Improved voltage thanks to the reduction of voltage drops in conductor;
  • Different type of loads can be compensated by using only one device;
  • Increased sustainability, thanks to the CO2 reduction of your power system’s demand charge.

Standards:

  • DIN EN 60439-1: 2012-06; VDE 0660-600-1: 2012-06
  • DIN EN 61921 (VDE 0560-700): 2004-02

Origin: 100% made in Italy

 

 

AUTOMATIC POWER FACTOR CORRECTION SYSTEMS

Static capacitor banks with thyristors are available for loads with large and fast current fluctuations.

CBaS-3:

Gruppo Energia low-voltage capacitor bank made in Italy

 

For more information, please consult the table below: 

Construction three-phase Intact Plus Capacitors
Voltage range 220 V to 690 V
Frequency 50 Hz / 60 Hz
Power range 50 kVar to 2000 kVar
Insulating voltage 690 V
Temperature range min. -40°C – max. 55° C
Service continuous
IP after mounting IP40 (IP54 and others upon request)
Inner surface finish zinc passivation
Use indoor (outdoor upon request)

Other power and voltage levels are available upon request. Don’t hesitate to contact us for any further information

 

 

 

CBaF-3: 

Capacitor bank with detuned harmonic reactors

For more information, please consult the table below: 

Construction three-phase Capacitors
Voltage range 220 V to 690 V
Reactors relative impedance P=5,67% / P=7% / P= 14% filter
Frequency 50 Hz/ 60 Hz
Tuning frequency

210 Hz / 250 Hz

189 Hz / 230 Hz

134 Hz / 160 Hz

Power range 50 kVar to 2000 kVar
Insulating voltage 690 V
Temperature range min. -40°C / max. 55° C
Service continuous
IP after mounting IP 40 (IP54 and others upon request)
Inner surface finish zinc passivation
Use indoor (outdoor upon request)

Other configurations are available upon request. For more information, don’t hesitate to contact us.